New Office Cabling Planning Specialists

The Network Installers plans and installs office cabling for new-office buildouts and relocations, engineering each cable plant to the ANSI/TIA-568 standard so your IT and facilities teams get day-one-ready connectivity. BICSI-certified technicians run, terminate, and test the cabling, backed by 19+ years and more than 20,000 business locations served nationwide, from single-floor suites to multi-building campuses.

Get A Free Quote

🔒︎  Your information will be kept Private

19+

Years Experience

20k+

Locations Protected

99%

Satisfaction Rating

Our Office Cabling Planning Process, From Site Survey to Certified Drops

Office cabling planning starts with a site survey, not a cable order. We walk your floor plan with your IT and facilities team and mark every drop location: workstations, conference rooms, wireless access points, security cameras, printers, and the server room or network closet. From that map we design a structured cabling system to the ANSI/TIA-568 standard and size the drop count for growth, adding spare capacity so a growing office is not re-cabled a year later. We place the main distribution frame (MDF) and any intermediate distribution frames (IDF) to keep horizontal runs within the 90-meter limit, then route pathways, conduit, and cable trays away from power lines to avoid interference. The same plan works whether you are building a new office or moving into one, so cabling is installed, tested, and labeled before move-in day. Planning a new space? Our office cabling services start with a site survey and a labeled drop plan you can budget from.

One Cable Plant for Your Data and Security Systems

Most offices run data, phones, cameras, and access control over the same low-voltage backbone, so we plan one cable plant for all of it. Designing data and security cabling together means one contractor, one set of pathways, and no second mobilization when you add cameras or badge readers later. Our technicians have wired offices, campuses, and government facilities where the network and the security systems share the same infrastructure.

The Network Installers

Telecommunications service provider

Eileen Guichard
Eileen Guichard
2 years ago
Network Installers were fabulous to work with. Larry came out to our office to inspect and quote the project. They came out as scheduled and did the work. Great quality work and easy to have them in our office. I would highly recommend Larry and The network Installers!
Kurstin Montero
Kurstin Montero
2 years ago
On behalf of Regency Centers, I was tremendously grateful for the support The Network Installers were able to provide during my recent office move. Larry Wertz assisted me, along with my offsite IT Team, as we navigated a couple of unforeseen challenges. His team of Technicians were knowledgeable and dependable, assisting us to achieve all our deadlines. Many thanks! Kurstin Montero
Brandon McCallum
Brandon McCallum
a year ago
This group was great. Everyone that I talked to was friendly, helpful, and knew what they were doing. I was having issues for my small business's IT systems, and they were quick to come out and get it fixed. If I have any issues, I will absolutely reach out to them again, and I highly recommend them to anyone looking for IT support.

Structured Cabling Components We Install in Your Office

A structured cabling system is more than cable. We install and terminate the full stack: patch panels and network racks in the server room, cable trays and raceways that carry runs overhead, conduit where cable needs protection, and work-area outlets at each desk. We build with Belden and Panduit components and label the runs so your IT team can trace any connection later. 

close-up of a network device showing green and yellow LED indicators
_server rack with multiple networking devices

Cat6, Cat6A, and Fiber: Choosing the Right Office Cabling

The right cable depends on speed and distance, not brand. Cat6 handles 10 Gbps over shorter runs and fits most workstations, while Cat6A carries 10 Gbps across the full 100-meter channel, with room to grow. For backbone runs between floors, single-mode fiber carries the most data the farthest. Cabling is designed to the ANSI/TIA-568 standard and kept within the 90-meter permanent-link limit, then tested and certified before handover. 

What Drives Your Office Cabling Cost

Office cabling is priced per drop, one cable run from the closet to a wall outlet. Your total depends on the number of drops, the cable type (Cat6, Cat6A, or fiber), run difficulty, and whether the job needs after-hours work or certified testing. We quote your project after a site walk of your floor plan, and the price covers materials, labor, and certification.

network switch with blue Ethernet cables plugged in

FAQs

Newer office buildings use structured cabling built on Category 6 (Cat6) or Category 6A (Cat6A) copper for workstations and single-mode fiber for backbone runs between floors. Cat6A supports 10 Gigabit Ethernet across a full 100-meter channel, which gives a new office room to grow into faster network speeds.

A cabling specialist designs, installs, tests, and certifies the network cabling that carries a building’s data, voice, and often its security signals. They plan drop locations, size the system for growth, and terminate and label every run to the ANSI/TIA-568 standard so the network performs reliably and stays easy to service.

Fiber optic cabling is the highest-performance choice for network backbones, with the greatest bandwidth and longest reach. Most offices pair a fiber backbone with Cat6A copper to the desk, since fiber handles heavy building-wide traffic while Cat6A delivers 10 Gbps to each workstation at a lower cost.

Structured cabling has six subsystems under the ANSI/TIA-568 standard. Entrance facilities are where outside services enter the building. The equipment room houses the core network gear. Backbone cabling connects the equipment room to the telecom rooms. Telecom rooms, or IDFs, serve each floor or zone. Horizontal cabling runs from the telecom room to each work area. Work-area components are the outlets and patch cords at the desk.

Plan at least two drops per workstation, one for the computer and one for a phone or a spare. Add dedicated drops for wireless access points, security cameras, printers, and conference-room equipment, which is why a 50-desk office needs far more than 50 drops. Plan the spare capacity before the walls close up.

Design the cabling to the ANSI/TIA-568 standard and plan spare capacity beyond today’s headcount. Keep data cable separated from electrical lines to avoid interference, and stay within the 90-meter permanent-link limit. Label runs to the TIA-606 standard, and test drops with certification reports rather than spot-checking a sample.

Office cabling is estimated on a per-drop basis, then multiplied by the number of drops. The per-drop figure moves with the cable type, how difficult the runs are to pull, labor, and whether the job includes certified testing. A site walk gives the most accurate number because it accounts for your actual floor plan and ceiling access.

Blog

Why Offices Choose The Network Installers for Cabling

IT directors and facilities managers choose The Network Installers because one team plans, installs, tests, and stands behind the cabling. We are BICSI-certified, hold a C7 Low Voltage License (#1039579), and install as a certified Belden and Panduit installer. From our California headquarters we run multi-site rollouts nationwide with the same standards at every location. We hand off test results and one point of accountability for warranty support. Contact us to scope your office cabling project.

Let’s start a conversation.